<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-19 08-33-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 69 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 3.0 kHz 85 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19020 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,1 dBr 2,17 dBr 3,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Montrealin sinfoniaorkesteri, Hutchins Timothy (Huilu) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2025/01/19 8.32.36 Total samples: 19020 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 3,8 dBr MIN: -0,1 dBr AVE: 2,17 dBr % above 12,2 dBr: 0,0 Last value: 3,2 dBr (2025/01/19 8.32.36) 08.18 08.20 08.22 08.24 08.26 08.28 08.30 08.32 -1 0 1 2 3 4 Pm [dBr]